Expertise in sterile pharmaceuticals, aseptic manufacturing processes, regulatory requirements, and technologies for pharmaceutical production.
Knowledge article in alphabetical order
Autoclaving is a physical sterilization process used for items including equipment components in the First Air zone, tools, or materials. During this process, items are sterilized in a pressure-resistant vessel using saturated steam under defined temperature, pressure, and exposure time. This reliably eliminates bacteria, fungi, and other microorganisms.
Barrier systems protect aseptic processes by separating the Grade A environment from the surrounding area. In RABS, interventions are performed through controlled glove access ports. Isolators provide complete separation of the product and process from personnel and are biodecontaminated before production begins.
Bio-decontamination is a process used to reduce biological contaminants such as microorganisms and other microbes to safe levels. Various methods can be used for this purpose, including gassing, fogging, or flash evaporation.
A Contamination Control Strategy (CCS) is required to be implemented in accordance with Annex 1. It links technical, organizational, and procedural controls throughout the entire manufacturing process. It defines critical control points and evaluates the combined effectiveness of all measures.
Direct product-contact parts are in direct contact with the product. Indirect product-contact parts do not directly contact the product itself but may touch other sterilized surfaces or components whose sterility is critical to the final product. Both categories are considered contamination-critical and must be sterilized in accordance with Annex 1.
Environmental monitoring involves the systematic monitoring of the manufacturing environment to detect particulate and microbiological contamination at an early stage. This includes activities such as particle counting as well as air and surface monitoring.
Annex 1 is part of the EU GMP Guide. It defines requirements for the manufacture, control, and release of sterile medicinal products and components. One of its core concepts is the Contamination Control Strategy (CCS), which is designed to ensure sterility and protect patient safety.
A filter integrity test is used to verify the integrity of a filtration system before and/or after its use. Depending on the filter type and application, different test methods may be employed, including the bubble-point test, diffusion test, water intrusion test, and pressure hold test.
"First Air" refers to sterile-filtered air whose airflow continuously reaches the product and product-contact machine parts without interruption. It protects critical surfaces from airborne contamination. Accordingly, Annex 1 requires Grade A conditions with unidirectional airflow in the critical zone for open isolators and RABS systems.
PUPSIT (Pre-Use Post-Sterilization Integrity Testing) refers to a specific integrity test that verifies the integrity of a sterilized filter assembly after sterilization. It is performed immediately before production and serves as an additional assurance measure within the aseptic manufacturing process.
Sterilization is a process that destroys or inactivates microorganisms such as bacteria, fungi, and other contaminants. While decontamination reduces microbial contamination to an acceptable level, sterilization aims to achieve the absence of viable microorganisms. Depending on the application, thermal, chemical, or radiation-based sterilization methods are used.
“Working Position” refers to the area of a machine, typically the opening of the primary packaging container, such as a vial opening, where critical and quality-relevant processes take place, including filling, stoppering, or gassing. For these areas, Annex 1 defines airflow requirements to ensure the protection of both the product and the process.